Alltech
ELECTRICAL SAFETY PROGRAM
Welcome to Alltech's Electrical Safety Program
This is your gateway to electrical safe work practices and procedures for this equipment.
Electrical Equipment Profile
Asset ID
Equipment Type
Device Type
Room / Area
Description
Shock & Arc Flash Hazards Profile
Nominal Voltage
Limited Approach Boundary
Shock Hazard
Incident Energy
Arc Flash Boundary
Arc Flash Hazard
AF Study
Next Assessment
Normal Operating Condition Profile
?
Properly Installed
?
Properly Maintained
?
Within AIC Rating
?
Approved Use
?
Covers Secured
?
Enclosure Intact
?
Impending Failures
Last Assessed
Last PM
Last Program Audit
Powered by GetESPTag — Connecting People, Equipment, and Safe Work Practices
Shock & Arc Flash PPE · Alltech ESP
PPE Requirements
Shock & Arc Flash PPE Requirements
NFPA 70E Article 120 · ESWC
Lockout / Tagout
Electrically Safe Work Condition
Asset-Specific Isolation Points
Energy isolation sequence
1
Notify affected employees
Inform all personnel that equipment must be shut down and isolated.
2
Normal equipment shutdown
Use normal stopping procedure to shut down equipment.
3
Operate energy isolation device
Open, close, block, or disconnect all energy sources.
4
Apply lockout devices
Apply personal lock(s) to each energy isolating device.
5
Release stored energy
Release, restrain, or discharge all residual energy.
6
Verify zero energy — Live-Dead-Live
Test known live source → test equipment → retest live source to confirm meter function.
NFPA 70E 130.2(B) · Justified Energized Work
Energized Work Permit
EEWP — Management authorization required
Energized work is only permitted under justified conditions with an approved permit
NFPA 70E 130.2(B) — Select one
Justification for energized work
1
De-energizing introduces additional or increased hazard
2
De-energizing is infeasible due to equipment design or operational limitations
3
Task requires energized state — diagnostics, testing, or troubleshooting
EEWP Checklist — Under Construction
Detailed permit checklist, approval signature fields, and expiry tracking will be built here.
Scope Change · Alltech ESP
Scope Change
Work scope has changed — document what was performed
Scope Change
Document Scope Change
This will create a new log record linked to your original JSP number.
Original JSP Number
Work Performed
Equipment Left In
I confirm that the work described above was performed under the Alltech Electrical Safety Program. The equipment has been left in the condition stated above and all energy controls have been removed or maintained as appropriate.
I acknowledge and confirm the above
Logged as a new record linked to the original JSP number.
Job Safety Plan — Alltech ESP
⛔ ESWC Required
Tier 2 Not Permitted
An Electrically Safe Work Condition is required before work begins.
⚡ Upstream Isolation Point
De-energize at the upstream point. Establish LOTO. Verify absence of voltage before work begins.
I understand — ESWC required. I will select a Tier 3 de-energize task to proceed.
ESP Field Resources · Alltech
Other Resources
Control
Reference
Document
✓ JSP closed — Completion Log updated
JSP Active · Alltech ESP
Work in Progress
Document work performed and close out your JSP
In Progress
JSP Number
Task
Work Performed
● Listening — speak now
Equipment Condition at Close
I confirm that the work described above was performed under the Alltech Electrical Safety Program. The equipment has been left in the condition stated above and all energy controls have been removed or maintained as appropriate.
I acknowledge and confirm the above
Logged to the Completion Log and linked to the active JSP.
Report an Observation
📷
Tap to add a photo Opens camera · optional
Observations are reviewed by the ESP Manager before any action is taken.
Observation Submitted
Thank you for helping improve electrical safety. Your observation has been submitted for review.